如何在时间间隔较短和Timer1_Tick更新数据库并重新绑定数据时顺利运行
本文关键字:新绑定 绑定 运行 数据 数据库 更新 时间 Tick Timer1 | 更新日期: 2023-09-27 17:50:01
当定时器间隔较短且定时器滴答时,运行数据库操作并更新asp.net web用户界面,我不能输入文本或选择下拉列表。
在实时操作数据库时如何做到不影响用户的操作?
如果有很多用户,恐怕会影响数据库的性能如慢
我已经设置它在更改时更新,但仍然相当频繁地干预操作,例如我不能选择下拉列表或不能在文本框中输入
</ContentTemplate>
<Triggers>
<asp:AsyncPostBackTrigger ControlID="Timer1" EventName="Tick" />
</Triggers>
</asp:UpdatePanel>
protected void Timer1_Tick(object sender, EventArgs e)
{
string[] last_serial_no = new string[Calculator_GridView.Rows.Count];
string[] last_a1_textbox = new string[Calculator_GridView.Rows.Count];
string[] last_b1_textbox = new string[Calculator_GridView.Rows.Count];
string[] last_mp_dropdown = new string[Calculator_GridView.Rows.Count];
bool change = false;
for (int i = 0; i < Calculator_GridView.Rows.Count; i++)
{
string serial_no = Calculator_GridView.Rows[i].Cells[1].Text;
string a1_textbox = Calculator_GridView.Rows[i].Cells[2].Text;
string b1_textbox = Calculator_GridView.Rows[i].Cells[3].Text;
DropDownList mp_dropdown = (DropDownList)Calculator_GridView.Rows[i].Cells[4].Controls[1];
//TextBox Result_textbox = (TextBox)Calculator_GridView.Rows[e.RowIndex].Cells[5].Controls[0];
if (last_serial_no[i] != serial_no ||
last_a1_textbox[i] != a1_textbox ||
last_b1_textbox[i] != b1_textbox ||
last_mp_dropdown[i] != mp_dropdown.SelectedValue)
{
string executestring = "";
executestring = "Update cal set a1=" + a1_textbox;
executestring = executestring + ", b1=" + b1_textbox;
executestring = executestring + ", mp=" + mp_dropdown.SelectedValue;
executestring = executestring + ", result=" + (Convert.ToDouble(mp_dropdown.SelectedValue) * Convert.ToDouble(b1_textbox)).ToString();
executestring = executestring + " where [識別碼]=" + serial_no;
ExecuteDatabase(executestring);
change = true;
}
last_serial_no[i] = serial_no;
last_a1_textbox[i] = a1_textbox;
last_b1_textbox[i] = b1_textbox;
last_mp_dropdown[i] = mp_dropdown.SelectedValue;
}
if (change == true)
{
string connstr = @"Provider=Microsoft.Jet.OLEDB.4.0;Data Source=|DataDirectory|/db1.mdb";
OleDbConnection conn = new OleDbConnection(connstr);
conn.ConnectionString = connstr;
try
{
conn.Open();
}
catch (Exception ex)
{
conn.Close();
}
OleDbCommand get_info_cmd = null;
get_info_cmd = new OleDbCommand("SELECT [識別碼], [a1], [b1], [result], [mp] FROM [cal]", conn);
OleDbDataReader get_info_Reader = get_info_cmd.ExecuteReader();
store.Columns.Add(new DataColumn("識別碼", typeof(int)));
store.Columns.Add(new DataColumn("a1", typeof(double)));
store.Columns.Add(new DataColumn("b1", typeof(double)));
store.Columns.Add(new DataColumn("mp", typeof(double)));
store.Columns.Add(new DataColumn("result", typeof(double)));
DataRow dr;
try
{
while (get_info_Reader.Read())
{
dr = store.NewRow();
dr[0] = get_info_Reader["識別碼"].ToString();
dr[1] = get_info_Reader["a1"].ToString();
dr[2] = get_info_Reader["b1"].ToString();
dr[3] = get_info_Reader["mp"].ToString();
dr[4] = (Convert.ToDouble(get_info_Reader["b1"].ToString()) * Convert.ToDouble(get_info_Reader["mp"].ToString())).ToString();
store.Rows.Add(dr);
}
}
catch (Exception ex)
{
Error_Label.Text = Error_Label.Text + ex.ToString();
conn.Close();
}
finally
{
get_info_cmd.Dispose();
get_info_Reader.Close();
conn.Close();
}
storeview = new DataView(store);
Calculator_GridView.Font.Size = new FontUnit(10);
Calculator_GridView.DataSourceID = "";
Calculator_GridView.DataSource = storeview;
Calculator_GridView.DataBind();
}
}
我认为您应该在单独的线程中执行DB操作。另外,你是如何更新ASP的?如前所述的网页?